Heavy Duty Construction - Long Life - High Duty Cycles - QuickShip Program - 100 to 2000 lb. Capacities - Speeds to 143 inches per minute - Stroke Length to 24 inches
- Multiple AC & DC Voltages - Clutch or Limit Switches - Optional Feedback -
Acme and Ball Screw Drive |
|
|
|
|
 |
-
Input Voltages of: 12 VDC or 24 VDC
-
Standard stroke lengths of: 2, 4, 6, 8, 10 and 12 inches
-
Adjustable limit switches - optional
-
Lifting speeds up to 60 in/min
- Pulse Generator - optional
|
|
| TracMaster™ Series |
Model |
Stroke Length(inches) |
Input Voltage |
Clutch |
Limit Switch |
Position
Feedback |
Machine or Ball Screw |
Duty
Cycle (In/Hr) |
Lifting Speed (In/Min) |
| TMD100 |
TMD01-1406 |
2,4,6,8,10,12
|
12 VDC
|
|
|
|
M
|
585
|
40
|
|
|
TMD01-1906
|
2,4,6,8,10,12
|
12 VDC
|
|
* |
|
M
|
450
|
40
|
|
|
TMD01-2406
|
2,4,6,8,10,12
|
24 VDC
|
|
|
|
M
|
900
|
60
|
|
|
TMD01-2906 |
2,4,6,8,10,12 |
24 VDC |
|
* |
|
M |
870 |
60
|
|
|
|
|
 |
-
Input Voltages of: 12 VDC or 24 VDC
-
Standard stroke lengths of: 2, 4, 6, 8, 10 and 12 inches
-
Lifting speeds up to 41 in/min
-
Adjustable limit switches - optional
-
Pulse generator - optional
|
|
| TracMaster™
Series |
Model
|
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr)
|
Lifting Speed (In/Min) |
|
TMD250
|
TMD02-1406 |
2,4,6,8,10,12 |
12 VDC |
|
|
|
M |
375 |
24 |
| |
TMD02-1906 |
2,4,6,8,10,12 |
12 VDC |
|
*
|
|
M |
330
|
24
|
|
|
TMD02-2406 |
2,4,6,8,10,12 |
24 VDC |
|
|
|
M |
630
|
45
|
|
|
TMD02-2906 |
2,4,6,8,10,12 |
24 VDC |
|
* |
|
M
|
495
|
45
|
|
|
|
 |
-
Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, 12 VDC and 24 VDC
-
Standard stroke lengths
of: 3,6,12, and 18 inches
-
Lifting speeds up to 86 in/min for AC models and 143 in/min for DC models
-
Offered with
fully adjustable internal limit
switches or travel/load limiting friction disc clutches.
-
Potentiometer - optional
|
|
| TracMaster™ Series |
Model |
Stroke Length
(inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr) |
Lifting Speed (In/Min) |
| TMA250-MP |
SPB3405
|
3,6,12,18
|
115 VAC (60 Hz) |
* |
|
|
M |
575 |
40 |
|
|
SPB4405 |
3,6,12,18 |
220 VAC
(50 Hz) |
* |
|
|
M |
435 |
34 |
|
|
HSPB3405 |
3,6,12,18 |
115 VAC (60 Hz) |
* |
|
|
M |
500 |
86 |
| TMD250-MP |
MPD3405 |
3,6,12,18 |
12 VDC |
* |
|
|
M |
1250 |
60 |
|
|
MPD3404 |
3,6,12,18 |
24 VDC
|
*
|
|
|
M
|
1200
|
66
|
|
|
HMPD3405 |
3,6,12,18
|
12 VDC
|
*
|
|
|
M
|
1000
|
143
|
| TMAL250-MP |
MPB3905
|
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
|
M
|
575
|
40
|
|
|
MPB4905
|
3,6,12,18
|
220 VAC (50 Hz) |
|
*
|
|
M
|
435
|
34
|
|
|
HMPB3905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
|
M
|
500
|
86
|
|
|
PMPB3905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
*
|
M
|
575
|
40
|
|
|
PMPB4905 |
3,6,12,18
|
220 VAC (50 Hz) |
|
*
|
*
|
M
|
435
|
34
|
|
|
PHMPB3905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
86
|
| TMDL250-MP |
MPD3905 |
3,6,12,18
|
12 VDC
|
|
*
|
|
M
|
1250
|
60
|
|
|
MPD3904 |
3,6,12,18
|
24 VDC
|
|
*
|
|
M
|
1200
|
66
|
|
|
HMPD3905 |
3,6,12,18
|
12 VDC
|
|
*
|
|
M
|
1000
|
143 |
|
|
|

|
-
Input Voltages of: 115 VAC, 60 Hz,
220 VAC, 50 Hz, 12 VDC and 24 VDC
-
Standard stroke lengths of: 3,6,12, and
18 inches
-
Lifting speeds up to 79"/min for AC models and 50"/min for DC models
-
Offered with fully adjustable internal limit
switches or travel/load limiting friction disc clutches.
-
Potentiometer - optional
|
|
| TracMaster™
Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr) |
Lifting Speed (In/Min) |
| TMA500-MP |
SPB6405 |
3,6,12,18
|
115VAC (60 Hz) |
*
|
|
|
M
|
500
|
35
|
|
|
SPB7405
|
3,6,12,18
|
220 VAC (50 Hz) |
*
|
|
|
M
|
435
|
32
|
|
|
HSPB6405 |
3,6,12,18
|
115 VAC (60 Hz) |
*
|
|
|
M
|
500
|
79
|
| TMD500-MP |
MPD6405 |
3,6,12,18 |
12 VDC
|
*
|
|
|
M
|
450
|
44
|
|
|
MPD6404 |
3,6,12,18
|
24 VDC
|
*
|
|
|
M
|
500 |
50
|
| TMAL500-MP |
MPB6905
|
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
|
M
|
500
|
35
|
|
|
MPB7905
|
3,6,12,18
|
220 VAC (50 Hz) |
|
*
|
|
M
|
435
|
32
|
|
|
HMPB6905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
|
M
|
500
|
79
|
|
|
PMPB6905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
35
|
|
|
PMPB7905 |
3,6,12,18
|
220 VAC (50 Hz) |
|
*
|
*
|
M
|
435
|
32
|
|
|
PHMPB6905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
79
|
| TMDL500-MP |
MPD6905 |
3,6,12,18
|
12 VDC
|
|
*
|
|
M
|
450
|
44
|
|
|
MPD6904 |
3,6,12,18
|
24 VDC
|
|
*
|
|
M
|
500
|
50
|
|
|
|

|
-
Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, 12 VDC and 24 VDC
-
Standard stroke lengths of: 4,8 and 12 inches
-
Lifting speeds up to 54" /min for AC models and 27" /min for DC
models
-
Fully adjustable internal limit switches are standard on AC models.
-
Clutch is standard on DC models
-
Potentiometer - optional on AC models
|
|
| Series |
Capacity |
Model |
Stroke |
Input
Voltage |
Clutch |
Limit
Switch |
Position
Feedback |
Machine or
Ball Screw |
Duty |
Lifting
Speed
(in/min) |
| TA500 |
500 |
TAL05-1A10- |
4,8,12 |
115 VAC,
(60 Hz) |
|
* |
|
M |
17.5% |
52 |
| TA500 |
500 |
TAP05-1A10- |
4,8,12 |
115 VAC,
(60 Hz) |
|
* |
* |
M |
17.5% |
52 |
| TA500 |
500 |
TAL05-2A10- |
4,8,12 |
220 VAC,
(50,60 Hz) |
|
* |
|
M |
17.0% |
54 (60 Hz) |
| TA500 |
500 |
TAP05-2A10- |
4,8,12 |
220 VAC,
(50,60 Hz) |
|
* |
* |
M |
17.0% |
54 (60 Hz) |
| TA500 |
500 |
TAC05-1D20- |
4,8,12 |
12 VDC |
* |
|
|
M |
40.0% |
27 |
| TA500 |
500 |
TAC05-2D20- |
4,8,12 |
24 VDC |
* |
|
|
M |
40.0% |
27 |
|
| TA1000 |
1000 |
TAL10-1A20- |
4,8,12 |
115 VAC,
(60 Hz) |
|
* |
|
M |
17.5% |
26 |
| TA1000 |
1000 |
TAP10-1A20- |
4,8,12 |
115 VAC,
(60 Hz) |
|
* |
* |
M |
17.5% |
26 |
| TA1000 |
1000 |
TAL10-2A20- |
4,8,12 |
220 VAC,
(50,60 Hz) |
|
* |
|
M |
17.5% |
27(60 Hz) |
| TA1000 |
1000 |
TAP10-2A20- |
4,8,12 |
220 VAC,
(50,60 Hz) |
|
* |
* |
M |
17.5% |
27(60 Hz) |
|
|
|

|
-
Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, and 12 VDC
-
Standard stroke lengths of: 3,6,12, 18 and 24 inches
-
Lifting speeds up to 50" /min for AC models and 26" (685 mm)/min for
DC models
-
Offered with fully adjustable internal limit switches or travel/load
limiting friction disc clutches.
-
Potentiometer - optional
|
|
| TracMaster™
Series |
Model |
Stroke Length
(inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball
Screw |
Duty Cycle† (In/Hr) |
Lifting Speed
(In/Min) |
| TMD1500-SP |
SPD6415 |
3,6,12,18,24 |
12 VDC |
* |
|
|
M
|
400 |
26 |
| TMAL1500-SP |
SPA6415 |
3,6,12,18,24 |
115 VAC (60 Hz) |
|
* |
|
M |
500 |
50 |
| |
SPA7415 |
3,6,12,18,24
|
220 VAC (50 Hz) |
|
*
|
|
M |
600
|
41
|
| |
PSPA6415 |
3,6,12,18,24
|
115 VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
50
|
| |
PSPA7415 |
3,6,12,18,24
|
220 VAC (50 Hz) |
|
*
|
*
|
M
|
600
|
41
|
| TMDL1500-SP |
LSPD6415 |
3,6,12,18,24
|
12 VDC |
|
*
|
|
M
|
400
|
26
|
|
|
|

|
-
Input Voltages of: 115 VAC, 60 Hz or 220 VAC, 50 Hz
-
Standard stroke lengths of: 3,6,12, 18 and 24 inches
-
Lifting speeds up to 52 in/min
-
Fully adjustable internal limit switches are standard.
-
Potentiometer - optional
|
|
| TracMaster™
Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle† (In/Hr) |
Lifting Speed (In/Min) |
| TMD2000-SP |
SPD6420 |
3,6,12,18,24
|
12 VDC
|
*
|
|
|
B
|
600
|
27
|
| TMAL2000-SP |
SPA6420 |
3,6,12,18,24
|
115 VAC (60 Hz) |
|
*
|
|
B
|
600
|
52
|
| |
SPA7420 |
3,6,12,18,24
|
220 VAC (50 Hz) |
|
*
|
|
B
|
625
|
41
|
| |
PSPA6420 |
3,6,12,18,24
|
115 VAC (60 Hz)
|
|
*
|
*
|
B
|
600
|
52
|
| |
PSPA7420 |
3,6,12,18,24
|
220 VAC (50 Hz) |
|
*
|
*
|
B
|
625
|
41
|
|
|
|
|