| Electromechanical
Actuator- Duff-Norton manufactures electromechanical actuators,
mechanical actuators (screw jacks), linear actuators, ball screw actuators,
machine screw actuators, electric cylinders, rollerscrews, rotary unions
(rotating joints), and air jacks. Electromechanical Linear Actuator Products
include TracMaster and LinearMaster Actuators, Packaged Controls, Modular
Actuators and PowerMaster Motor Cylinders and Synchro Cylinders. This
Duff-Norton product line of actuators features load capacities ranging from 100
pounds to 100 Tons, gear or belt drives, acme screw and ball screw systems with
various AC and DC input voltages. Packaged Controls operate the extend and
retract function of the actuator and are available for all Duff-Norton
TracMaster and LinearMaster Electromechanical Linear Actuators. Duff-Norton
Electromechanical Actuation Products are specially designed for a variety of
commercial and industrial applications. These actuators are used for opening
and closing, tilting and pivoting, lifting and lowering and positioning.
Applications include gates, dampers, oven and processing tank doors, antennas,
orthopedic tables and other medical equipment, ergonomic furniture, and
agricultural equipment, etc. Custom design is also available for special
applications. Electromechanical linear actuators are now being used in place of
pneumatics and hydraulics when high maintenance and environmental problems
(leaking hydraulic oil) are a concern. |
|
|
|
|
 |
-
Input Voltages of: 12 VDC or 24 VDC
-
Standard stroke lengths of: 2, 4, 6, 8, 10 and 12 inches
-
Adjustable limit switches - optional
-
Lifting speeds up to 60 in/min
-
Pulse Generator - optional
|
|
| TracMaster™
Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr) |
Lifting Speed
(In/Min) |
| TMD100 |
TMD01-1406 |
2,4,6,8,10,12
|
12 VDC
|
|
|
|
M
|
585
|
40
|
| |
TMD01-1906
|
2,4,6,8,10,12
|
12 VDC
|
|
* |
|
M
|
450
|
40
|
| |
TMD01-2406
|
2,4,6,8,10,12
|
24 VDC
|
|
|
|
M
|
900
|
60
|
| |
TMD01-2906 |
2,4,6,8,10,12 |
24 VDC |
|
* |
|
M |
870 |
60
|
|
|
|
|
 |
-
Input Voltages of: 12 VDC or 24 VDC
-
Standard stroke lengths of: 2, 4, 6, 8, 10 and 12 inches
-
Lifting speeds up to 41 in/min
-
Adjustable limit switches - optional
-
Pulse generator - optional
|
|
| TracMaster™
Series |
Model
|
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position
Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr)
|
Lifting Speed (In/Min) |
|
TMD250
|
TMD02-1406 |
2,4,6,8,10,12 |
12 VDC |
|
|
|
M |
375 |
24 |
| |
TMD02-1906 |
2,4,6,8,10,12 |
12 VDC |
|
*
|
|
M |
330
|
24
|
| |
TMD02-2406 |
2,4,6,8,10,12 |
24 VDC |
|
|
|
M |
630
|
45
|
| |
TMD02-2906 |
2,4,6,8,10,12 |
24 VDC |
|
* |
|
M
|
495
|
45
|
|
|
|
 |
-
Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, 12 VDC and 24 VDC
-
Standard stroke lengths of: 3,6,12, and 18 inches
-
Lifting speeds up to 86 in/min for AC models and 143 in/min for DC
models
-
Offered with fully adjustable internal limit switches or travel/load
limiting friction disc clutches.
-
Potentiometer - optional
|
|
| TracMaster™
Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr) |
Lifting Speed (In/Min) |
| TMA250-MP |
SPB3405
|
3,6,12,18
|
115 VAC (60 Hz) |
* |
|
|
M |
575 |
40 |
| |
SPB4405 |
3,6,12,18 |
220 VAC (50 Hz) |
* |
|
|
M |
435 |
34 |
| |
HSPB3405 |
3,6,12,18 |
115 VAC (60 Hz) |
* |
|
|
M |
500 |
86 |
| TMD250-MP |
MPD3405 |
3,6,12,18 |
12 VDC |
* |
|
|
M |
1250 |
60 |
| |
MPD3404 |
3,6,12,18 |
24 VDC
|
*
|
|
|
M
|
1200
|
66
|
| |
HMPD3405 |
3,6,12,18
|
12 VDC
|
*
|
|
|
M
|
1000
|
143
|
| TMAL250-MP |
MPB3905
|
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
|
M
|
575
|
40
|
| |
MPB4905
|
3,6,12,18
|
220 VAC (50 Hz) |
|
*
|
|
M
|
435
|
34
|
| |
HMPB3905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
|
M
|
500
|
86
|
| |
PMPB3905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
*
|
M
|
575
|
40
|
| |
PMPB4905 |
3,6,12,18
|
220 VAC (50 Hz) |
|
*
|
*
|
M
|
435
|
34
|
| |
PHMPB3905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
86
|
| TMDL250-MP |
MPD3905 |
3,6,12,18
|
12 VDC
|
|
*
|
|
M
|
1250
|
60
|
| |
MPD3904 |
3,6,12,18
|
24 VDC
|
|
*
|
|
M
|
1200
|
66
|
| |
HMPD3905 |
3,6,12,18
|
12 VDC
|
|
*
|
|
M
|
1000
|
143 |
|
|
|

|
-
Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, 12 VDC and
24 VDC
-
Standard stroke lengths of: 3,6,12, and 18 inches
-
Lifting speeds up to 79"/min for AC models and 50"/min for DC models
-
Offered with fully adjustable internal limit switches or travel/load
limiting friction disc clutches.
-
Potentiometer - optional
|
|
| TracMaster™
Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle (In/Hr) |
Lifting Speed (In/Min) |
| TMA500-MP |
SPB6405 |
3,6,12,18
|
115VAC (60 Hz) |
*
|
|
|
M
|
500
|
35
|
| |
SPB7405
|
3,6,12,18
|
220 VAC (50 Hz) |
*
|
|
|
M
|
435
|
32
|
| |
HSPB6405 |
3,6,12,18
|
115 VAC (60 Hz) |
*
|
|
|
M
|
500
|
79
|
| TMD500-MP |
MPD6405 |
3,6,12,18 |
12 VDC
|
*
|
|
|
M
|
450
|
44
|
| |
MPD6404 |
3,6,12,18
|
24 VDC
|
*
|
|
|
M
|
500 |
50
|
| TMAL500-MP |
MPB6905
|
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
|
M
|
500
|
35
|
| |
MPB7905
|
3,6,12,18
|
220 VAC (50 Hz) |
|
*
|
|
M
|
435
|
32
|
| |
HMPB6905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
|
M
|
500
|
79
|
| |
PMPB6905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
35
|
| |
PMPB7905 |
3,6,12,18
|
220 VAC (50 Hz) |
|
*
|
*
|
M
|
435
|
32
|
| |
PHMPB6905 |
3,6,12,18
|
115 VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
79
|
| TMDL500-MP |
MPD6905 |
3,6,12,18
|
12 VDC
|
|
*
|
|
M
|
450
|
44
|
| |
MPD6904 |
3,6,12,18
|
24 VDC
|
|
*
|
|
M
|
500
|
50
|
|
|
|

|
-
Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, 12 VDC and 24 VDC
-
Standard stroke lengths of: 4,8 and 12 inches
-
Lifting speeds up to 54" /min for AC models and 27" /min for DC
models
-
Fully adjustable internal limit switches are standard on AC models.
-
Clutch is standard on DC models
-
Potentiometer - optional on AC models
|
|
| Series |
Capacity |
Model |
Stroke |
Input
Voltage |
Clutch |
Limit
Switch |
Position
Feedback |
Machine or
Ball Screw |
Duty |
Lifting
Speed
(in/min) |
| TA500 |
500 |
TAL05-1A10- |
4,8,12 |
115 VAC,
(60 Hz) |
|
* |
|
M |
17.5% |
52 |
| TA500 |
500 |
TAP05-1A10- |
4,8,12 |
115 VAC,
(60 Hz) |
|
* |
* |
M |
17.5% |
52 |
| TA500 |
500 |
TAL05-2A10- |
4,8,12 |
220 VAC,
(50,60 Hz) |
|
* |
|
M |
17.0% |
54 (60 Hz) |
| TA500 |
500 |
TAP05-2A10- |
4,8,12 |
220 VAC,
(50,60 Hz) |
|
* |
* |
M |
17.0% |
54 (60 Hz) |
| TA500 |
500 |
TAC05-1D20- |
4,8,12 |
12 VDC |
* |
|
|
M |
40.0% |
27 |
| TA500 |
500 |
TAC05-2D20- |
4,8,12 |
24 VDC |
* |
|
|
M |
40.0% |
27 |
|
| TA1000 |
1000 |
TAL10-1A20- |
4,8,12 |
115 VAC,
(60 Hz) |
|
* |
|
M |
17.5% |
26 |
| TA1000 |
1000 |
TAP10-1A20- |
4,8,12 |
115 VAC,
(60 Hz) |
|
* |
* |
M |
17.5% |
26 |
| TA1000 |
1000 |
TAL10-2A20- |
4,8,12 |
220 VAC,
(50,60 Hz) |
|
* |
|
M |
17.5% |
27(60 Hz) |
| TA1000 |
1000 |
TAP10-2A20- |
4,8,12 |
220 VAC,
(50,60 Hz) |
|
* |
* |
M |
17.5% |
27(60 Hz) |
|
|
|
|
|

|
-
Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, 12 VDC and 24 VDC
-
Standard stroke lengths of: 3,6,12, 18 and 24 inches
-
Lifting speeds up to 53" /min for AC models and 39" /min for DC
models
-
Fully adjustable internal limit switches are standard
-
Potentiometer - optional
|
|
| TracMaster™ Series |
Model |
Stroke Length
(inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle† (In/Hr) |
Lifting Speed
(In/Min) |
| TMAL1000-HD |
SPA 3410
|
3,6,12,18,24 |
115 VAC (60 Hz) |
|
* |
|
B |
900
|
53 |
| |
SPA 4410
|
3,6,12,18,24
|
220 VAC (50 Hz)
|
|
*
|
|
B |
1000
|
50
|
| |
PSPA 3410
|
3,6,12,18,24
|
115 VAC (60 Hz)
|
|
*
|
*
|
B
|
900
|
53
|
| |
PSPA 4410 |
3,6,12,18,24
|
220 VAC (50 Hz)
|
|
*
|
*
|
B |
1000
|
50
|
|
|
|
|
|

|
-
Input Voltages of: 115 VAC, 60 Hz, 220 VAC, 50 Hz, and 12 VDC
-
Standard stroke lengths of: 3,6,12, 18 and 24 inches
-
Lifting speeds up to 50" /min for AC models and 26" (685 mm)/min for
DC models
-
Offered with fully adjustable internal limit switches or travel/load
limiting friction disc clutches.
-
Potentiometer - optional
|
|
| TracMaster™
Series |
Model |
Stroke Length
(inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball
Screw |
Duty Cycle† (In/Hr) |
Lifting Speed
(In/Min) |
| TMD1500-SP |
SPD6415 |
3,6,12,18,24 |
12 VDC |
* |
|
|
M
|
400 |
26 |
| TMAL1500-SP |
SPA6415 |
3,6,12,18,24 |
115 VAC (60 Hz) |
|
* |
|
M |
500 |
50 |
| |
SPA7415 |
3,6,12,18,24
|
220 VAC (50 Hz) |
|
*
|
|
M |
600
|
41
|
| |
PSPA6415 |
3,6,12,18,24
|
115 VAC (60 Hz) |
|
*
|
*
|
M
|
500
|
50
|
| |
PSPA7415 |
3,6,12,18,24
|
220 VAC (50 Hz) |
|
*
|
*
|
M
|
600
|
41
|
| TMDL1500-SP |
LSPD6415 |
3,6,12,18,24
|
12 VDC |
|
*
|
|
M
|
400
|
26
|
|
|
|

|
-
Input Voltages of: 115 VAC, 60 Hz or 220 VAC, 50 Hz
-
Standard stroke lengths of: 3,6,12, 18 and 24 inches
-
Lifting speeds up to 52 in/min
-
Fully adjustable internal limit switches are standard.
-
Potentiometer - optional
|
|
| TracMaster™
Series |
Model |
Stroke Length (inches) |
Input Voltage |
Clutch |
Limit Switch |
Position Feedback |
Machine or Ball Screw |
Duty Cycle† (In/Hr) |
Lifting Speed (In/Min) |
| TMD2000-SP |
SPD6420 |
3,6,12,18,24
|
12 VDC
|
*
|
|
|
B
|
600
|
27
|
| TMAL2000-SP |
SPA6420 |
3,6,12,18,24
|
115 VAC (60 Hz) |
|
*
|
|
B
|
600
|
52
|
| |
SPA7420 |
3,6,12,18,24
|
220 VAC (50 Hz) |
|
*
|
|
B
|
625
|
| | | |